RAID controllers and cache memory |
- Dual independent controllers, each with environment management coprocessor for out-of-band remote management and monitoring
- 512MB of cache per controller (1GB total)
- Cache Backup Battery Modules (sold separately) for over 72 hours of memory protection
|
RAID operation |
- Support for RAID levels: 0, 1, 3, 5, 0+1,10, 30, 50 (10, 30 and 50 require host-based software RAID)
- Support for multiple RAID sets, multiple hosts and LUN masking and mapping
- Background RAID set creation; automatic variable background rebuilding; online expansion; LUN slicing; global drive hot sparing (per RAID controller) (2)
|
Fibre Channel storage-to-host connection |
- Dual 2Gb Fibre Channel ports (SFP), 200MB/s throughput per channel with guaranteed delivery (400MB/s full duplex) (3)
- Host connectivity using 2Gb Apple Fibre Channel PCI-X Card or Apple Fibre Channel PCI Express Card (cards sold separately) or compatible third-party PCI card
- Support for point-to-point, loop and fabric (switched) topologies
- Dual 10/100BASE-T Ethernet for remote management
|
Apple Fibre Channel PCI Express Card (sold separately) |
- Dual-channel 2Gb Fibre Channel PCI Express Bus Adapter
- Runs at full bandwidth in a four-lane or eight-lane PCI Express slot on the new Power Mac G5; not compatible with PCI or PCI-X
- Two 2.9-meter Fibre Channel copper cables with embedded SFP transceivers; compatible with SFP fiber-optic cables and transceivers
|
Apple Fibre Channel PCI-X Card (sold separately) |
- 64-bit, 133MHz card with two SFP 2Gb Fibre Channel ports; compatible with 32-bit, 66MHz PCI slots and 64-bit, 100 MHz or 133 MHz PCI-X slots
- Two 2.9-meter Fibre Channel copper cables with embedded SFP transceivers; compatible with SFP fiber-optic cables and transceivers
|
Supported SFP Types |
Short-Haul Transceiver (supports up to 500m with 50/125 m MMF)
- Finisar FTRJ-8519-P1BNL
- Pico Light PL-XPL-VE-S24-11
- Pico Light PL-XPL-VC-S23-11
- JDS Uniphase JSM-21S0AA1
- JDS Uniphase JSP-21S0AA1
Long-Haul Transceiver (supports up to 10km with 9/125 m SMF)
|
Cooling |
- Redundant hot-swap cooling modules with self-regulating speeds and front-to-back cooling
- Environmental monitoring system for automatically maintaining optimal ambient temperature
|
Electrical requirements |
- Redundant load-sharing hot-swap power supplies (450W); universal input (100V to 240V AC), power factor corrected
- Maximum input current: 7.6A (100V to 127V) or 3.6A (200V to 240V)
- Power usage: 300W typical continuous power, 400W maximum continuous power
- Dual DB-9 serial ports for UPS systems
- Frequency: 50Hz to 60Hz, single phase
|
Environmental requirements |
- Operating temperature: 50° to 95° F (10° to 35° C)
- Storage temperature: -40° to 116° F ( -40° to 47° C)
- Relative humidity: 5% to 95% noncondensing
- Maximum thermal output: 1365 BTUs per hour
- Maximum altitude: 10,000 feet
- FCC Class A approved
|
Size and weight |
- 3U rack-optimized: 5.25 inches (13.3 cm) high by 17 inches (43.2 cm) wide by 18.4 inches (46.7 cm) deep
- Fits EIA-310-D-compliant industry-standard 19-inch-wide four-post racks from 24 to 36 inches deep; deeper racks require third-party extender
- 60-100 pounds (27-45 kg), depending on configuration (4)
|