PROBLEM DESCRIPTION: The Monitor II displays a single line
across the screen. There is no other display.
CAUSE: Yoke wires might not be connected properly.
CURE: Check the connections for the green/white pair of yoke
wires and make sure they are properly connected to the main
electronics assembly. At present they are connected to location
V-DY (center of main electronics assembly).