Here is a problem that may occur with Kinetics FastPath 4:
Symptoms:
- Affected FastPaths may reset at irregular intervals, resulting in a loss
of network configuration and zones (i.e. the indicator lights on the
front panel cycle continuously).
- On power up, the unit may not pass self-verification (i.e. all front
panel indicator lights are on continuously).
Problem Description/Fix:
The DC power cable harness that connects the power supply to the main PRINTED
CIRCUIT BOARD assembly may become loose, causing interference with the voltage
regulation circuitry. To insure a consistent supply of voltage to the PRINTED
CIRCUIT BOARD, the cable should be soldered to the power supply and PRINTED
CIRCUIT BOARD.
All units manufactured since 1 October 1989 have this fix incorporated. The
ECN (Engineering Change Notice) level has changed to #2446, Rev. N, which is
stamped on the outside of the shipping box.
(NOTE: "Rev. J" still appears on the UNDERSIDE of the corrected FastPath unit.)
Solutions for units in the field:
Warranty rework is provided for FastPath 4s displaying the above symptoms.
Please contact Novell Customer Service for help.
For more information, search under: "Novell"